Author Topic: Etymotic Research ER-4S measurement  (Read 1984 times)

0 Members and 1 Guest are viewing this topic.

speakerphone

  • Powder Monkey
  • *
  • Brownie Points: +23/-0
  • Offline Offline
  • Posts: 52
Re: Etymotic Research ER-4S measurement
« Reply #10 on: March 20, 2015, 05:20:12 PM »

Is it possible to share this file ?

Yes I can share this, but maybe you can't use this unless you have artificial ears, because of impedance mismatch.
You have to compensate acoustical impedance mismatch between a 2-cc coupler and an occluded ear simulator, first.
You can reference
http://rinchoi.blogspot.kr/2012/09/akg-k3003-part3-in-depth-analysis.html?m=1
Measurement data difference between そのべ's and Rin's.

speakerphone

  • Powder Monkey
  • *
  • Brownie Points: +23/-0
  • Offline Offline
  • Posts: 52
Re: Etymotic Research ER-4S measurement
« Reply #11 on: March 20, 2015, 05:25:21 PM »

Plus,
http://goldenears.net/board/1506729

 Article about acoustical impedance mismatch {RECD (Real Ear to Coupler Difference)} compensation. You should use Translator to read this.
« Last Edit: March 20, 2015, 05:57:46 PM by speakerphone »
Logged

MuZo2

  • Able Bodied Sailor
  • Pirate
  • ***
  • Brownie Points: +10/-2
  • Offline Offline
  • Posts: 201
Re: Etymotic Research ER-4S measurement
« Reply #12 on: March 24, 2015, 09:03:51 PM »

Can you check measurements for W4 and VSD5 and see if DF compensation is correct? I would like to try with your file too.
Logged

speakerphone

  • Powder Monkey
  • *
  • Brownie Points: +23/-0
  • Offline Offline
  • Posts: 52
Re: Etymotic Research ER-4S measurement
« Reply #13 on: March 26, 2015, 12:01:28 AM »

Can you check measurements for W4 and VSD5 and see if DF compensation is correct? I would like to try with your file too.

Actually, there is many varieties of DF file,
 because Diffuse Field is not a specific target, it is just a way to get a Target.
Can you explain more about your measurement condition?